EPA v. KIMBLE GLASS INC.
Case summary
Kimble stated that it had conducted an investigation into the cause of the excess opacity levels and determined that a faulty electrostatic precipitator (ESP) was likely the cause. Kimble had the ESP repaired and, by a Section 114 request by U.S. EPA, conducted a particulate matter (PM) stack test to verify compliance with both the visual emissions limit and the PM emissions limit. The stack test indicated compliance with both limitations. However, based on historical repair records, the operating performance of Kimbles ESP has been poor. As a result, Kimble has agreed to monitor stack opacity levels via a continuous opacity monitor (COMS) coincident with ESP performance parameters to insure long-term compliance with the visual emission limit.
Defendants (1)
- KIMBLE GLASS INC.Named in complaintNamed in settlement
Facilities (1)
GERRESHEIMER MOULDED GLASS CHICAGO INC.
1131 ARNOLD ST, CHICAGO HEIGHTS, IL, 60411-2904
Registry ID: 110000432443
Statutes cited
- CAA 502 — Operating Permits (Title V)
- CAA 110 — Implementation Plan for National Primary and Secondary Ambient Air Quality Standards
Enforcement conclusions (1)
KIMBLE GLASS INC.entered 2006-09-27
Primary law: CAA
Timeline (2 milestones)
- 2006-09-27Final Order Issued
- 2006-09-29Enforcement Action Data Entered
Case metadata
- EPA activity ID
- 600011052
- Case number
- 05-2006-6007
- Lead agency
- EPA
- EPA region
- 05
- Voluntary self-disclosure
- No
- Primary statute
- Operating Permits (Title V)
Sourced verbatim from EPA ECHO Enforcement Case Report for case 05-2006-6007 . Bulk data: ICIS-FEC download summary.
This is legal information, not legal advice. Laws vary by jurisdiction and change frequently. Always verify current law with official sources and consult a licensed attorney in your jurisdiction for advice on your specific situation.