Skip to main content
02-2009-1212Administrative - FormalClosedFY 2009· Region 02

EPA v. Eastman Kodak Company

Final Order With Penalty

Case summary

This action addresses violations of EPA’s CFC regulations for Kodak’s failure to properly perform CFC leak repairs on appliances on CFC units containing more than 50 pounds of refrigerant and for failure to conduct initial and follow-up verification tests. A Final Order assessed a civil monetary penalty against Kodak.

Defendants (1)

  • Eastman Kodak CompanyNamed in complaintNamed in settlement

Facilities (2)

  • MONROE COMMUNITY COLLEGE

    321 STATE ST|FKA PART OF 343 STATE ST, ROCHESTER, NY, 14650

    Registry ID: 110000809019

  • MONROE COMMUNITY COLLEGE

    321 STATE ST|FKA PART OF 343 STATE ST, ROCHESTER, NY, 14650

    Registry ID: 110000809019

Statutes cited

  • CAA 608National Recycling & Emission Reduction Program

Enforcement conclusions (1)

  • Eastman Kodak Companyentered 2009-09-16

    Primary law: CAA

    Federal penalty: $63,792

Timeline (4 milestones)

  • 2009-04-09Complaint Filed/Proposed Order
  • 2009-07-09Enforcement Action Data Entered
  • 2009-09-16Final Order Issued
  • 2009-09-16Enforcement Action Closed

Case metadata

EPA activity ID
1800004865
Case number
02-2009-1212
Lead agency
EPA
Branch
AIR
EPA region
02
Voluntary self-disclosure
No
Primary statute
National Recycling & Emission Reduction Program

Sourced verbatim from EPA ECHO Enforcement Case Report for case 02-2009-1212 . Bulk data: ICIS-FEC download summary.