Safety Standard for Automatic Residential Garage Door Operators
Primary source
Metadata and text below are from the Federal Register, a public-domain U.S. government work. Always verify the official published version before relying on it for any legal matter.
Issuing agencies
Abstract
In October 2025, updates to the entrapment protection provisions in the UL 325 standard were accepted under the Consumer Product Safety Improvement Act of 1990 (Improvement Act) for inclusion in the Commission's mandatory safety regulation for automatic residential garage door operators. In this direct final rule, the Consumer Product Safety Commission (Commission) is amending the Commission's automatic residential garage door operators mandatory regulation to align with the changes in UL 325.
Full Text
<html>
<head>
<title>Federal Register, Volume 91 Issue 209 (Friday, October 30, 2026)</title>
</head>
<body><pre>
[Federal Register Volume 91, Number 209 (Friday, October 30, 2026)]
[Rules and Regulations]
[Pages 68456-68460]
From the Federal Register Online via the Government Publishing Office [<a href="http://www.gpo.gov">www.gpo.gov</a>]
[FR Doc No: 2026-22213]
=======================================================================
-----------------------------------------------------------------------
CONSUMER PRODUCT SAFETY COMMISSION
16 CFR Part 1211
[Docket No. CPSC-2015-0025]
Safety Standard for Automatic Residential Garage Door Operators
AGENCY: U.S. Consumer Product Safety Commission.
ACTION: Direct final rule.
-----------------------------------------------------------------------
SUMMARY: In October 2025, updates to the entrapment protection
provisions in the UL 325 standard were accepted under the Consumer
Product Safety Improvement Act of 1990 (Improvement Act) for inclusion
in the Commission's mandatory safety regulation for automatic
residential garage door operators. In this direct final rule, the
Consumer Product Safety Commission (Commission) is amending the
Commission's automatic residential garage door operators mandatory
regulation to align with the changes in UL 325.
DATES: The rule is effective on December 29, 2026, unless we receive
significant adverse comments by November 30, 2026. If we receive a
timely significant adverse comment, we will publish a notification in
the Federal Register, withdrawing this direct final rule before its
effective date. The incorporation by reference of certain material
listed in this rule is approved by the Director of the Federal Register
as of December 29, 2026. The incorporation by reference of certain
other material listed in this rule was approved by the Director as of
May 9, 2016.
ADDRESSES: You can submit comments, identified by Docket No. CPSC-2015-
0025, by any of the following methods:
Electronic Submissions: Submit electronic comments to the Federal
eRulemaking Portal at: <a href="https://www.regulations.gov">https://www.regulations.gov</a>. Follow the
instructions for submitting comments. CPSC typically does not accept
comments submitted by email, except as described below.
Confidential Written Submissions: CPSC encourages you to submit
electronic comments by using the Federal eRulemaking Portal. If you
wish to submit confidential business information, trade secret
information, or other sensitive or protected information that you do
not want to be available to the public, you may submit such
[[Page 68457]]
comments by email to <a href="/cdn-cgi/l/email-protection#ec8f9c9f8fc1839fac8f9c9f8fc28b839a"><span class="__cf_email__" data-cfemail="f596858696d89a86b596858696db929a83">[email protected]</span></a>.
Instructions: All submissions must include the agency name and
docket number. CPSC may post all comments without change, including any
personal identifiers, contact information, or other personal
information provided, to: <a href="https://www.regulations.gov">https://www.regulations.gov</a>. Do not submit to
this website: confidential business information, trade secret
information, or other sensitive or protected information that you do
not want to be available to the public. If you wish to submit such
information, please submit it according to the instructions for
confidential written submissions.
Docket: For access to the docket to read background documents or
comments received, go to: <a href="https://www.regulations.gov">https://www.regulations.gov</a>, and insert the
docket number, CPSC-2015-0025, into the ``Search'' box, and follow the
prompts.
FOR FURTHER INFORMATION CONTACT: Julio Alvarado, Compliance Officer,
U.S. Consumer Product Safety Commission, 441 G Street NW, Washington,
DC 20548; telephone: (301) 504-7418; email: <a href="/cdn-cgi/l/email-protection#650f040913041704010a25061516064b020a13"><span class="__cf_email__" data-cfemail="bed4dfd2c8dfccdfdad1feddcecddd90d9d1c8">[email protected]</span></a>; or Jay
Kadiwala, Electrical Engineer, U.S. Consumer Product Safety Commission,
National Product Testing & Evaluation Center, 5 Research Place, Suite
101-09, Rockville, MD 20850; telephone (301) 987-2517; email:
<a href="/cdn-cgi/l/email-protection#95fffef4f1fce2f4f9f4d5f6e5e6f6bbf2fae3"><span class="__cf_email__" data-cfemail="42282923262b35232e2302213231216c252d34">[email protected]</span></a>.
SUPPLEMENTARY INFORMATION:
I. Background
Section 203(a) and (b) of the Improvement Act, Public Law 101-608,
states that the entrapment protection requirements of UL 325,
``Standard for Safety for Door, Drapery, Gate, Louver, and Window
Operators and Systems,'' (UL 325), are considered a consumer product
safety rule under the Consumer Product Safety Act (CPSA). 15 U.S.C.
2056 Note. On June 19, 1991, as mandated by the Improvement Act, the
Commission issued a final rule codifying the provisions of the
entrapment protection requirements of UL 325 at 16 CFR part 1211. 56 FR
28050. On December 21, 1992, as directed in section 203(b) of the
Improvement Act, the Commission published a final rule to include the
additional entrapment protection provisions adopted by UL in UL 325 in
the CPSC mandatory standard for automatic residential garage door
operators. 57 FR 60449.
Section 203(c) of the Improvement Act requires UL to notify CPSC of
any revisions to UL 325, which is the basis for the Commission's garage
door operator (GDO) regulation. When UL notifies the Commission of a
revision, that revision ``shall be incorporated in the consumer product
safety rule . . . unless, within 30 days of such notice, the Commission
notifies [UL] that the Commission has determined that such revision
does not carry out the purposes of subsection (b)'' of section 203 of
the Improvement Act, which initially mandated the UL 325 entrapment
protection requirements. As provided in the Improvement Act, the
Commission has revised the GDO standard several times following UL
notification to the Commission of changes to the entrapment protection
requirements of UL 325. The Commission last updated the GDO rule in
2024, to reflect changes made to the entrapment protection provisions
of UL 325 up to that time. 89 FR 18538 (Mar. 24, 2024).
On September 23, 2025, UL notified the Commission of revisions to
UL 325 regarding the entrapment protection provisions related to
residential garage door operators. In October 2025, in accordance with
the procedure in the Improvement Act, the Commission accepted for
inclusion in its mandatory standard the relevant revisions to UL 325
regarding the entrapment protection requirements for automatic
residential GDOs. To implement the revisions to UL 325 for residential
GDOs in the Commission mandatory standard, this direct final rule
revises the provisions of the GDO rule at 16 CFR part 1211 to reflect
the earlier acceptance of the revisions for the entrapment protection
requirements for automatic residential GDOs in UL 325, Seventh
Edition.\1\
---------------------------------------------------------------------------
\1\ The Commission voted 3-0 to publish this notification.
---------------------------------------------------------------------------
II. Changes to UL 325
Since the last update of the mandatory GDO regulation in 2024,
there has been one published revision to UL 325: Seventh Edition,
published on September 15, 2025. The revisions to UL 325 regarding the
entrapment protection requirements for automatic residential GDOs are
discussed in detail below.
A. Battery Powered Applications
Two new sections, 33.2.2.11 (GDOs Employing Battery Backup
(Vertical Moving Doors) and 33.2.3.11 (GDOs Employing Battery Backup
(Horizontally Sliding Doors), were added to UL 325. These provisions
have new test requirements in sections 33.2.2.12 and 33.2.3.12,
respectively, to ensure that the entrapment protection operations
function under backup battery power but do not function if there is not
enough battery power for the garage door operator to complete an open/
close cycle. In this circumstance, the system verifies there is enough
battery charge to perform both an open and close cycle and if the
system cannot do that function, the door will remain open and the
entrapment protection system rendered inoperable, which causes the door
to be inoperable, until the battery is charged or AC mains power is
restored. The performance tests are conducted on the battery back-up at
the lowest operational voltage (battery must be fully charged and then
discharged to the manufacturer's specified lowest operating voltage) to
ensure that the battery has enough stored energy for the operator to
detect an object and open the door when there is no AC power. These new
requirements support the purpose of the Improvement Act by ensuring the
GDO will function to prevent entrapment even when AC power is cut and
the system is powered by the battery backup at the lowest operational
voltage.
B. Clarifications for Monitoring for Secondary Entrapment Protection
for Residential Garage Door Operators Requirements
Residential garage door operator systems monitor the presence of
the secondary entrapment protection device to ensure that it is ready
for operation at least once during each close cycle. If the secondary
entrapment protection device is not detected by the system circuit, is
disconnected from the circuit, or there is an error in the device, the
door will not operate. Section 33.3.3 of the UL standard currently
states ``operator shall monitor for the presence and correct operation
of the device at least once during each close cycle.''
The revision to section 33.3.3 of UL 325 (contained in 16 CFR
1211.8(c)) also removes the phrase ``and correct operation'' regarding
the secondary entrapment protection device. The UL 325 Technical
Committee made this change because there is no practical way to
determine what the ``correct operation'' is to allow for testing to
determine whether GDO systems were specifically meeting this
requirement. Detecting the presence of the secondary entrapment
protection device is sufficient to ensure the secondary entrapment
protection device is functional and will respond if the primary system
fails.
C. Instruction Manual Section
The revisions to UL 325 sections 60.1.14 (currently contained in 16
CFR 1211.16(a)(10)) and 60.3 (contained in 16 CFR 1211.16(a)(2)) remove
inaccurate and misleading references to ``residential garage doors.''
Section
[[Page 68458]]
60.3.2 states that ``[a] residential garage door operator or system
shall be provided with complete and specific instructions for . . .
satisfactory operation of the door.'' This change clarifies that the
printed instructions required by UL 325 only apply to a garage door
that is part of a residential garage door operator system and not a
garage door by itself. This revision allows manufacturers to accurately
communicate this information to consumers.
III. Description of the Direct Final Rule
The direct final rule amends 16 CFR part 1211 to include the
revisions regarding the entrapment protection requirements for
automatic residential GDOs in UL 325, Seventh Edition discussed above.
All revisions in the direct final rule concern the GDO regulation in
subpart A and D of part 1211. The direct final rule does not change any
of the certification (subpart B), or recordkeeping (subpart C)
provisions of the GDO regulation.
The revisions to 16 CFR part 1211 are described as follows.
<bullet> Changes to section 1211.4. Section 1211.4 updates the
reference to UL 325:2025 and adds a new paragraph (d) stating the
requirements of the rule also cover battery-powered operators,
including operators with battery back-up systems.
<bullet> Changes to section 1211.5. Section 1211.5 updates the
reference to UL 325:2025.
<bullet> Changes to section 1211.7. Section 1211.7 adds new
paragraphs (b)(11), (b)(12), (c)(11), and (c)(12) with requirements for
vertical and horizontal garage door operators employing a battery back-
up system.
<bullet> Changes to section 1211.8. Section 1211.8(c) deletes the
phrase ``and correct operation'' as the phrase is unnecessary because
there is no practical way to determine what the ``correct operation''
is to allow for testing to determine whether GDO systems were
specifically meeting this requirement. Section 1211.8(f) adds language
from a previous revision to the standard that was inadvertently left
out of the rule to be consistent with the language of the voluntary
standard.
<bullet> Changes to section 1211.16. Section 1211.16(a)(2), (3),
and (10)(i) add clarifying language ``or system'' after garage door
operator to indicate it may apply to a whole system and not just the
garage door operator, if applicable.
<bullet> Changes to section 1211.16. Section 1211.40(d)(1) updates
the reference UL 325:2025 and adds Supplement C to the incorporation by
reference.
This direct final rule amends the mandatory GDO rule at 16 CFR part
1211 to include the revisions to the entrapment protection requirements
for automatic residential GDOs in UL 325:2025, Seventh Edition.
IV. Incorporation by Reference
Sections 1211.4, 1211.5, 1211.7, and 1211.40 of the direct final
rule incorporate by reference provisions in UL 325:2025. The Office of
the Federal Register (OFR) has regulations regarding incorporation by
reference. 1 CFR part 51. Under these regulations, agencies must
discuss in the preamble of a final rule ways in which material the
agency incorporates by reference is reasonably available to interested
parties and how interested parties can obtain the material. In
addition, the preamble to the final rule must summarize the material. 1
CFR 51.5(b).
In accordance with the OFR regulations requiring a summary of the
material in the voluntary standard, UL 325:2025, Standard for Door,
Drapery, Gate, Louver, and Window Operators and Systems covers
performance requirements, test methods, and labeling requirements for
residential garage door operators, drapery, louver, and window operator
systems.
UL 325:2025 is copyrighted. UL 325:2025 is reasonably available to
interested parties in several ways. A read-only copy of the revised
standard UL 325:2025 is available to view at no cost on UL's website at
<a href="http://www.ulstandards.com/IBR/logon.aspx">www.ulstandards.com/IBR/logon.aspx</a>. Additionally, interested parties
can purchase a copy of the UL standard from UL, 151 Eastern Avenue,
Bensenville, IL 60106, Telephone: 1-888-853-3503 or online at:
<a href="http://www.shopulstandards.com">www.shopulstandards.com</a>. Finally, interested parties can schedule an
appointment to inspect a copy of the standard at CPSC's Office of the
Secretary, U.S. Consumer Product Safety Commission, 441 G Street NW,
Washington, DC 20548, telephone: 301-504-7479; email: <a href="/cdn-cgi/l/email-protection#3b584b48581654487b584b4858155c544d"><span class="__cf_email__" data-cfemail="d2b1a2a1b1ffbda192b1a2a1b1fcb5bda4">[email protected]</span></a>.
UL 1998 is also referenced in the amendatory text of this document,
but is already approved for use in that section (Sec. 1211.8).
V. Direct Final Rule Process
The Commission is issuing this rule as a direct final rule.
Although the Administrative Procedure Act (APA; 5 U.S.C. 551-559)
generally requires agencies to provide notice of a rule and an
opportunity for interested parties to comment on it, section 553 of the
APA provides an exception when the agency ``for good cause finds'' that
notice and comment are ``impracticable, unnecessary, or contrary to the
public interest.'' Id. 553(b)(B).
The Commission concludes that notice and comment are not necessary
here because the Commission is taking the limited action of amending
the GDO rule to conform the regulation to the relevant changes made to
UL 325 that were previously accepted in October 2025 under the
Improvement Act. Because this document merely updates the GDO rule to
reflect the previously accepted changes to UL 325, the Commission
considers this rulemaking to be a non-controversial matter that is not
likely to generate comments. Public comment will not impact the
acceptance of the substantive changes to UL 325 under the Improvement
Act that has previously occurred. Additionally, public comments would
not alter substantive changes to the standard or the effect of the
revised standard as a consumer product safety standard under section
203(a) of the Improvement Act. Under these circumstances, notice and
comment are unnecessary. Therefore, the Commission concludes that the
direct final rule process is appropriate.
In Recommendation 2024-6, the Administrative Conference of the
United States (ACUS) endorses direct final rulemaking as an appropriate
procedure to expedite rules that are noncontroversial and that are not
expected to generate significant adverse comments. See 89 FR 106406
(Dec. 30, 2024). ACUS recommends that agencies use the direct final
rule process when they act under the ``unnecessary'' prong of the good
cause exemption in 5 U.S.C. 553(b)(B). 89 FR 106406, 106409. Consistent
with the ACUS recommendation, the Commission is publishing this rule as
a direct final rule, because CPSC does not expect any significant
adverse comments.
Unless CPSC receives a significant adverse comment within 30 days
of this notification, the rule will become effective on December 29,
2026. In accordance with ACUS's recommendation, the Commission
considers a significant adverse comment to be one where the commenter
explains why the rule would be inappropriate, ``including challenges to
the rule's underlying premise or approach,'' or where the commenter
explains why the rule would be ineffective or unacceptable without
change. Id. at 106409. If the Commission receives a significant adverse
comment, the Commission will withdraw any portion of this direct final
rule related to such a comment. Depending on the comment and other
circumstances, the Commission may then incorporate the adverse comment
into a subsequent
[[Page 68459]]
direct final rule or publish a notice of proposed rulemaking, providing
an opportunity for public comment.
VI. Regulatory Flexibility Act
The Regulatory Flexibility Act (RFA; 5 U.S.C. 601-612) generally
requires agencies to review proposed and final rules for their
potential economic impact on small entities, including small
businesses, and prepare regulatory flexibility analyses. 5 U.S.C. 603,
604. The RFA applies to any rule that is subject to notice and comment
procedures under section 553 of the APA. Id. As discussed in section V.
Direct Final Rule Process of this preamble, the Commission has
determined that notice and the opportunity to comment are unnecessary
for this rule. Therefore, the RFA does not apply. CPSC also notes the
limited nature of this document, which merely updates the GDO rule to
conform the regulation to the applicable changes made to UL 325 under
the Improvement Act.
VII. Paperwork Reduction Act
The current mandatory standard for garage door operators includes
labeling and instruction manual requirements that constitute a
``collection of information,'' as defined in the Paperwork Reduction
Act (PRA; 44 U.S.C. 3501-3521). While the rule clarifies language
regarding the description of products subject to the rule in the
instruction manual section of the rule, the clarifications do not add
to the burden hours because the products already require marking and
labeling. Because the information collection burden is essentially
unchanged, the revision does not affect the information collection
requirements or approval related to the standard.
VIII. Effective Date
Because the changes to the entrapment protection requirements of
the UL 325 standard are not substantial and the industry has had more
almost a year since publication of the revised UL 325 voluntary
standard to come into compliance with its entrapment protection
revisions, 60 days is sufficient for the effective date. Therefore, the
effective date of the direct final rule is December 29, 2026.
IX. Preemption
Section 203(f) of the Improvement Act contains a provision
preempting under 15 U.S.C. 2075 those provisions of laws of States or
political subdivisions which relate to the labeling of automatic
residential garage door openers and those provisions which do not
provide at least the equivalent degree of protection from the risk of
injury associated with automatic residential garage door openers as the
consumer product safety rule. 15 U.S.C. 2056 Note.
X. Environmental Considerations
Commission rules are categorically excluded from any requirement to
prepare an environmental assessment or an environmental impact
statement where they ``have little or no potential for affecting the
human environment.'' 16 CFR 1021.5(c). This rule falls within the
categorical exclusion, so no environmental assessment or environmental
impact statement is required.
XI. Congressional Review Act and Executive Order 12866
Pursuant to the Congressional Review Act (CRA) and Executive Order
(E.O.) 12866, the Office of Management and Budget's Office of
Information and Regulatory Affairs has determined that this rule does
not qualify as a ``major rule,'' as defined in 5 U.S.C. 804(2), and is
not a significant regulatory action as defined under section 2(f) of
E.O. 12866. To comply with the CRA, CPSC will submit the required
information to each House of Congress and the Comptroller General.
List of Subjects in 16 CFR Part 1211
Consumer protection, Imports, Incorporation by reference, Labeling,
Reporting and recordkeeping requirements.
For the reasons set forth in the preamble, the Commission amends 16
CFR part 1211 as follows:
PART 1211--SAFETY STANDARDS FOR AUTOMATIC RESIDENTIAL GARAGE DOOR
OPERATORS
0
1. The authority citation for part 1211 continues to read as follows:
Authority: 15 U.S.C. 2056 Note; 15 U.S.C. 2063 and 2065.
0
2. In Sec. 1211.4:
0
a. Amend paragraph (c) by removing the text ``UL 325-2017'' and adding,
in its place, the text ``UL 325:2025''; and,
0
b. Add paragraph (d).
The addition reads as follows:
Sec. 1211.4 General requirements for protection against risk of
injury.
* * * * *
(d) These requirements also cover battery-powered operators,
including operators with battery back-up systems, with user-replaceable
and/or non-user battery subject to the requirement of Sec. 1211.7 and
the applicable requirements of Supplement SC of UL 325:2025
(incorporated by reference, see Sec. 1211.40).
0
3. In Sec. 1211.5 amend the introductory text of paragraph (a) and
paragraph (b)(4) by removing the text ``UL 325-2017'' and adding, in
its place, the text ``UL 325:2025''.
0
4. Amend Sec. 1211.7 by adding paragraphs (b)(11) and (12) and (c)(11)
and (12) to read as follows:
Sec. 1211.7 Inherent primary entrapment protection requirements.
* * * * *
(b) * * *
(11) An operator employing a battery back-up system shall operate
as specified in paragraphs (b)(1), (2), and (3) of this section, as
applicable; or the operator is rendered inoperative (any case in which
the operator will not complete a full cycle, open, and close, of
travel) when tested in accordance with paragraph (b)(12) of this
section and the applicable requirements of Supplement SC of UL 325:2025
(incorporated by reference, see Sec. 1211.40).
(12) Compliance with paragraph (b)(11) of this section shall be
verified with a fully charged battery, and then with the same battery
after it has been discharged per the manufacturer's recommendations to
the operator's lowest operational voltage.
(c) * * *
(11) An operator employing battery back-up system shall operate as
specified in paragraphs (c)(1), (2), and (3) of this section as
applicable; or the operator is rendered inoperative (any case in which
the operator will not complete a full cycle, open and close, of travel)
when tested in accordance with paragraph (c)(12) of this section and
the applicable requirements of Supplement SC of UL 325:2025
(incorporated by reference, see Sec. 1211.40).
(12) Compliance with paragraph (c)(11) of this section shall be
verified with a fully charged battery, and then with the same battery
after it has been discharged per the manufacturer's recommendations to
the operator's lowest operational voltage.
* * * * *
0
5. In Sec. 1211.8:
0
a. Amend the introductory text of paragraph (c) by removing the text
``and correct operation''; and
0
b. Revise paragraph (f).
The revision reads as follows:
Sec. 1211.8 Secondary entrapment protection requirements.
* * * * *
(f) An inherent secondary entrapment protection device described in
[[Page 68460]]
Sec. 1211.6(b)(3) shall comply with the applicable requirements in
Sec. 1211.13, independent of the primary entrapment protection. The
independent primary and secondary entrapment protection devices shall
not use the same detection means nor measure the same physical
properties. Software used in an inherent secondary entrapment
protection device shall comply with UL 1998 (incorporated by reference,
see Sec. 1211.40).
0
6. Amend Sec. 1211.16 by revising paragraphs (a)(2) and (3), and
(a)(10)(i) to read as follows:
Sec. 1211.16 Instruction manual.
* * * * *
(a) * * *
(2) Instructions that clearly detail installation and adjustment
procedures required to effect proper operation of the safety means
provided shall be provided with each door operator (or system).
(3) A residential garage door operator or system shall be provided
with complete and specific instructions for the correct adjustment of
the control mechanism and the need for periodic checking and, if
needed, adjustment of the control mechanism so as to maintain
satisfactory operation of the door.
* * * * *
(10) * * *
(i) Residential garage door operators (or systems), instructions of
this section, as applicable.
* * * * *
0
7. Revise and republish Sec. 1211.40 to read as follows:
Sec. 1211.40 Incorporation by reference.
Certain material is incorporated by reference into this part with
the approval of the Director of the Federal Register under 5 U.S.C.
552(a) and 1 CFR part 51. All approved incorporation by reference (IBR)
material is available for inspection at the Consumer Product Safety
Commission (CPSC) and at the National Archives and Records
Administration (NARA). Contact CPSC at: Office of the Secretary,441 G
Street NW, Washington, DC 20548; phone (301) 504-7479; email: <a href="/cdn-cgi/l/email-protection#583b282b3b75372b183b282b3b763f372e"><span class="__cf_email__" data-cfemail="94f7e4e7f7b9fbe7d4f7e4e7f7baf3fbe2">[email protected]</span></a>. For information on the availability of this material at
NARA, visit <a href="http://www.archives.gov/federal-register/cfr/ibr-locations">www.archives.gov/federal-register/cfr/ibr-locations</a> or
email <a href="/cdn-cgi/l/email-protection#dabca8f4b3b4a9aabfb9aeb3b5b49ab4bba8bbf4bdb5ac"><span class="__cf_email__" data-cfemail="5a3c28743334292a3f392e3335341a343b283b743d352c">[email protected]</span></a>. The material may be obtained from the
following sources:
(a) Door and Access Systems Manufacturers' Association,
International (DASMA), 1300 Sumner Avenue, Cleveland, OH 44115-2851;
phone: (216) 241-7333; email: <a href="/cdn-cgi/l/email-protection#264247554b47664247554b470845494b"><span class="__cf_email__" data-cfemail="d0b4b1a3bdb190b4b1a3bdb1feb3bfbd">[email protected]</span></a>; website: <a href="http://www.dasma.com/dasma-standards/">www.dasma.com/dasma-standards/</a>.
(1) ANSI/DASMA 102, Specifications for Sectional Doors, 2011
revision, dated May 19, 2011; into Sec. 1211.6(c).
(2) [Reserved]
(b) National Fire Prevention Association (NFPA), 1 Batterymarch
Park, Quincy, MA 02269-9101; phone: (800) 344-3555; <a href="http://www.nfpa.org/">www.nfpa.org/</a>.
(1) NFPA 70, National Electrical Code, 2014 edition, effective
August 21, 2013; into Sec. 1211.2(c).
(2) [Reserved]
(c) UL Standards and Engagement (UL), 151 Eastern Avenue,
Bensenville, IL 60106; phone: 1-888-853-3503; website: <a href="https://shopulstandards.com/">https://shopulstandards.com/</a>.
(1) ANSI/CANUL 325:2025 (UL 325:2025), Standard for Safety: Door,
Drapery, Gate, Louver, and Window Operators and Systems, Seventh
Edition, Revision dated September 15, 2025; into Sec. Sec. 1211.4(c)
and (d); 1211.5; 1211.7(b) and (c).
(2) UL 746C, Standard for Safety: Polymeric Materials--Use in
Electrical Equipment Evaluations, Sixth Edition, dated September 10,
2004; into Sec. Sec. 1211.10(d) and (e); 1211.12(c).
(3) UL 991, Standard for Safety: Tests for Safety-Related Controls
Employing Solid-State Devices, Third Edition, dated October 22, 2004;
into Sec. Sec. 1211.4(c); 1211.5(b).
(4) UL 1998, Standard for Safety: Software in Programmable
Components, Third Edition, December 18, 2013; into Sec. 1211.8(f).
Note 1 to Sec. 1211.40: If the material listed in this section
is not available through the publisher's online store, it may be
necessary to contact the publisher directly.
Alberta E. Mills,
Secretary, U.S. Consumer Product Safety Commission.
[FR Doc. 2026-22213 Filed 10-29-26; 8:45 am]